Skip to content

Parameters & error codes ​

All parameters are reachable from the Façade 2024 config screens. Navigation logic:

  • OK enters / exits the page (exit without saving).
  • ▲ / ▼ selects the parameter to edit.
  • ◀ / ▶ increments / decrements the selected value.
  • SET exits the page with save.

Set quille (keel) ​

ParameterDescription
Rel PrtPort-side stop angle for Release mode.
Rel StrbStarboard-side stop angle for Release mode.
Stop PosValidation of the intermediate position stop.
OUI — enabled
NON — disabled
Stop PrtIntermediate stop angle on the port side.
Stop StrbIntermediate stop angle on the starboard side.
Inc +/-Angle increment for incremental movements.

Set Alim (power) ​

ParameterDescription
V minMinimum battery voltage for system operation.
V maxMaximum battery voltage for system operation.
I ChgCharging current of the supercapacitors.

Affichage (display) ​

ParameterDescription
Off DispValidates screen blanking after a period of inactivity.
OUI — enabled
NON — disabled
Off DlyDelay before screen blanking.
Off lvlMaximum backlight level in Off position.
On lvlMaximum backlight level in On position.

Error codes ​

CodeMeaningConsequenceRecovery
Pos AbsPosition sensor not detected.Position stops are inoperative. Angle stays at zero.Connect the sensor correctly.
Prt Pres AbsPort pressure sensor not detected.Pressure displays stay at zero. Lift detection disabled.Connect the sensor correctly.
Strb Pres AbsStarboard pressure sensor not detected.Pressure displays stay at zero. Lift detection disabled.Connect the sensor correctly.
OVLOBattery voltage too high (Over Voltage Lock Out).System stops. No movement possible.Bring the battery voltage back inside the limits.
UVLOBattery voltage too low (Under Voltage Lock Out).System stops. No movement possible.Bring the battery voltage back inside the limits.
Ev Rel Prt CCaShort circuit on the port Release valve drive.System stops.Restart the system after checking the wiring.
Ev Rel Strb CCAShort circuit on the starboard Release valve drive.System stops.Restart the system after checking the wiring.
Ev Prt CCAShort circuit on the port movement valve drive.System stops.Restart the system after checking the wiring.
Ev Strb CCAShort circuit on the starboard movement valve drive.System stops.Restart the system after checking the wiring.
Motor CCAShort circuit on the motor relay drive.System stops.Restart the system after checking the wiring.
Cap OverVoltageSupercapacitors over voltage.Charger stops.Discharge the supercapacitors.
Cap OverTempSupercapacitors over temperature.Charger stops.Wait for the supercapacitors to cool down.
Cap Not RespondingSupercapacitor charger silent on the bus.Capacitor-related displays disappear. The current limit programmed via the façades is no longer applied — the limit set by the charger's internal selector is used instead.Check the system network wiring.
CapOffSupercapacitor ON/OFF switch is in the OFF position.Charger is inoperative.Switch it back to ON.