Appearance
Parameters & error codes
All parameters are reachable from the Façade 2024 config screens. Navigation logic:
- OK enters / exits the page (exit without saving).
- ▲ / ▼ selects the parameter to edit.
- ◀ / ▶ increments / decrements the selected value.
- SET exits the page with save.
Set quille (keel)
| Parameter | Description |
|---|---|
Rel Prt | Port-side stop angle for Release mode. |
Rel Strb | Starboard-side stop angle for Release mode. |
Stop Pos | Validation of the intermediate position stop.OUI — enabledNON — disabled |
Stop Prt | Intermediate stop angle on the port side. |
Stop Strb | Intermediate stop angle on the starboard side. |
Inc +/- | Angle increment for incremental movements. |
Set Alim (power)
| Parameter | Description |
|---|---|
V min | Minimum battery voltage for system operation. |
V max | Maximum battery voltage for system operation. |
I Chg | Charging current of the supercapacitors. |
Affichage (display)
| Parameter | Description |
|---|---|
Off Disp | Validates screen blanking after a period of inactivity.OUI — enabledNON — disabled |
Off Dly | Delay before screen blanking. |
Off lvl | Maximum backlight level in Off position. |
On lvl | Maximum backlight level in On position. |
Error codes
| Code | Meaning | Consequence | Recovery |
|---|---|---|---|
Pos Abs | Position sensor not detected. | Position stops are inoperative. Angle stays at zero. | Connect the sensor correctly. |
Prt Pres Abs | Port pressure sensor not detected. | Pressure displays stay at zero. Lift detection disabled. | Connect the sensor correctly. |
Strb Pres Abs | Starboard pressure sensor not detected. | Pressure displays stay at zero. Lift detection disabled. | Connect the sensor correctly. |
OVLO | Battery voltage too high (Over Voltage Lock Out). | System stops. No movement possible. | Bring the battery voltage back inside the limits. |
UVLO | Battery voltage too low (Under Voltage Lock Out). | System stops. No movement possible. | Bring the battery voltage back inside the limits. |
Ev Rel Prt CCa | Short circuit on the port Release valve drive. | System stops. | Restart the system after checking the wiring. |
Ev Rel Strb CCA | Short circuit on the starboard Release valve drive. | System stops. | Restart the system after checking the wiring. |
Ev Prt CCA | Short circuit on the port movement valve drive. | System stops. | Restart the system after checking the wiring. |
Ev Strb CCA | Short circuit on the starboard movement valve drive. | System stops. | Restart the system after checking the wiring. |
Motor CCA | Short circuit on the motor relay drive. | System stops. | Restart the system after checking the wiring. |
Cap OverVoltage | Supercapacitors over voltage. | Charger stops. | Discharge the supercapacitors. |
Cap OverTemp | Supercapacitors over temperature. | Charger stops. | Wait for the supercapacitors to cool down. |
Cap Not Responding | Supercapacitor charger silent on the bus. | Capacitor-related displays disappear. The current limit programmed via the façades is no longer applied — the limit set by the charger's internal selector is used instead. | Check the system network wiring. |
CapOff | Supercapacitor ON/OFF switch is in the OFF position. | Charger is inoperative. | Switch it back to ON. |