Skip to content

CGS — generator set (function 26) ​

A generator set and its controller. It reports whether the controller is present and whether the set is driven, contactor-closed, safe-stopped or in fault, together with motor and controller temperatures, RPM, torque, load and the electrical power it is producing.

Published only (no commands). All frames expireAfterSec: 30.

Published ​

device/26/<i>/life ​

metadata adds counter. Enum pairs are disable/enable unless noted.

data fieldTypeUnitDescription
BindToParcint—Parc binding id
ControllerPresent / ControllerPresentCodestring / int—absent/present
contactorState / contactorStateCodestring / int—Contactor
drive / driveCodestring / int—Drive
safeStop / safeStopCodestring / int—Safe stop
fault / faultCodestring / int—noFault/faultPresent
boostFunction / boostFunctionCodestring / int—Boost function
voltagenumber (1 dec)VVoltage
currentnumber (1 dec)ACurrent
motorTemperatureint°CMotor temperature
controllerTemperatureint°CController temperature
json
{
  "data": {
    "BindToParc": 1,
    "ControllerPresent": "present",
    "ControllerPresentCode": 1,
    "contactorState": "enable",
    "contactorStateCode": 1,
    "drive": "enable",
    "driveCode": 1,
    "safeStop": "disable",
    "safeStopCode": 0,
    "fault": "noFault",
    "faultCode": 0,
    "boostFunction": "disable",
    "boostFunctionCode": 0,
    "voltage": 52.4,
    "current": 30.2,
    "motorTemperature": 45,
    "controllerTemperature": 40
  },
  "metadata": {
    "rxdate": "2026-06-17T14:30:45.123Z",
    "rxTimestamp": 1781793045,
    "expireAfterSec": 30,
    "counter": 9
  }
}

device/26/<i>/state ​

data fieldTypeUnitDescription
motorRpmnumber (0 dec)rpmMotor RPM
motorTorquenumber (1 dec)NmTorque
motorLoadint%Load
mechanicalPowernumber (0 dec)WMechanical power

device/26/<i>/state2 ​

data fieldTypeUnitDescription
motorLineToLineVoltagenumber (1 dec)VLine-to-line voltage
motorPhaseCurrentnumber (1 dec)APhase current
motorDcElectricalPowernumber (0 dec)WDC electrical power
bash
mosquitto_sub -h 127.0.0.1 -t 'device/26/+/#' -v

Integration of multiplexed solutions
MUXEN and the MUXEN logo are trademarks of MUXEN SAS.